How can solar power, battery storage and backup power work together to keep a property running during a power cut? In this episode of Senergia Play, we visit Åre and take a closer look at a system with 50 kW of inverter capacity, 100 kWh of battery storage and almost 100 kW of connected solar panels. With support for island mode, a UPS function and connection to a diesel generator, solar power and battery storage are combined with backup power for longer outages. We also look at what is needed to switch safely to island mode and how the system can be tailored to the property’s needs.

0:23
23 seconds
Hello, everyone. A very warm welcome to a new episode of Sen Play. I’ve made my way up to Åre, where I’m standing
0:29
29 seconds
next to one of the first CHS2 units to be installed. This is a combined inverter and battery storage system, with
0:37
37 seconds
an inverter capacity of 50 kW and battery storage of 100 kWh. What’s unique about this particular product is
0:45
45 seconds
that it can be connected to both a generator — a diesel generator for island mode — and it also has
0:54
54 seconds
UPS functionality. So if the power goes out, it can switch over and first power the property up here using the battery, and then the diesel generator can kick in if the solar panels aren’t generating enough. This system has almost 100 kW
1:10
1 minute, 10 seconds
of solar power connected to it, and even on an early winter’s day or early spring day like this, it produces almost
1:19
1 minute, 19 seconds
20 kW. And it’s very cloudy here today. The CS2 here has
1:26
1 minute, 26 seconds
six MPPTs, so you can connect quite a lot of solar panels across many different strings. And thanks to the option
1:34
1 minute, 34 seconds
of connecting a diesel generator, you really get the feeling that you can be self-sufficient.
1:40
1 minute, 40 seconds
And that’s something many people may not realise when they buy a solar installation: if the power goes out, there’s no guarantee that the inverter
1:48
1 minute, 48 seconds
they’ve chosen can operate in island mode or provide backup. So, as well as an inverter that supports this, you also need a local
1:57
1 minute, 57 seconds
earth electrode. We’ll also take a look at the local ATS, or automatic transfer switch, which switches from grid operation,
2:04
2 minutes, 4 seconds
disconnecting from the electricity grid and switching to island mode, to make sure that power isn’t fed
2:11
2 minutes, 11 seconds
back into the grid. So the C2 here is very compact and comes more or less ready to install. You simply lift
2:20
2 minutes, 20 seconds
it into place, ready from the factory, and it’s quite straightforward to connect the live, neutral
2:26
2 minutes, 26 seconds
and earth for the supply, and likewise for the island-mode connection, then connect the solar panels. So it’s
2:34
2 minutes, 34 seconds
quite quick to install. And because it’s rated at 50 kW, you can also run several in parallel
2:42
2 minutes, 42 seconds
if you need more kilowatt-hours or more kilowatts. This might not be the most common sight at a
2:50
2 minutes, 50 seconds
solar installation, but this is the diesel generator. It can power the whole property and has a built-in tank
2:59
2 minutes, 59 seconds
of just over 500 litres. Of course, you can connect additional tanks if you want, with a total capacity of up to a few thousand
3:08
3 minutes, 8 seconds
litres. It’s worth considering how long you want the diesel fuel to last, and what you need to power, and for
3:16
3 minutes, 16 seconds
how long. You may need to carry out a fairly extensive study to work out how many kilowatt-hours you consume
3:23
3 minutes, 23 seconds
per day, and how many days you need to be able to manage in island mode. Here, they’re well equipped and can manage for very long periods.
3:35
3 minutes, 35 seconds
This is a larger model of diesel generator, but in fact it’s becoming more and more common to connect a diesel generator directly to an inverter.
3:43
3 minutes, 43 seconds
There are, of course, many smaller diesel generators rated at 5, 10, 15 and 20 kW, which may be more suitable for a house. So this is a proper
3:51
3 minutes, 51 seconds
industrial application, and perhaps a bit over the top for most people, but it’s a very nice example to show the size and
3:58
3 minutes, 58 seconds
the S2 in combination with the diesel generator, creating the complete system that so many people have been waiting for and
4:06
4 minutes, 6 seconds
wanting. Some facts about the Size and S2 are that it has 100 kWh of storage and an inverter
4:15
4 minutes, 15 seconds
capacity of 50 kW. Its six MPPTs allow you to connect up to 100 kW, which is exactly what we’ve connected to this installation.
4:25
4 minutes, 25 seconds
It also has an air-source heat pump, which means it can both cool the system in summer
4:34
4 minutes, 34 seconds
and heat it so it can be installed outdoors. In this case, it’s in a cold store. And up here in northern Sweden, it’s good to keep
4:42
4 minutes, 42 seconds
the battery temperature at a suitable level every day of the year. It also has
4:49
4 minutes, 49 seconds
built-in fire safety, with warning and extinguishing systems integrated into the battery itself. So this is a fully
4:58
4 minutes, 58 seconds
equipped system we’re looking at here. Hey!

We know that it is not always easy to know which product or solution is best suited to your needs. Whether you have questions about our range, need guidance or would like help finding a solution tailored to your needs, we are here for you. With our knowledge and experience, we will help you make the right choice.