Introduction

How large a battery you can install in a villa or house is no longer just a technical question of wall space, power output and budget. Under the Swedish National Board of Housing, Building and Planning’s new fire-safety regulations (BFS 2024:7), location, fire compartment and escape safety are crucial in determining the size of energy-storage systems that may be installed – and under what conditions [2–4].

  • This post is aimed at you as an installer, and will help you to:
  • Explain to the customer why the battery’s location matters so much.
  • Assess when >20 kWh requires its own fire compartment – and when there is scope for larger batteries without breaching the regulations [4–5].
  • Understand how fire-engineered design can be used when standard solutions are not sufficient [2,3].

The aim is to provide a practical interpretation and concrete examples – not to replace a fire-safety consultant responsible for the design or the client’s responsibility [3,7].

It is important to point out that many people have not read or understood the new regulations. In this post on the technology blog, we will prove that it is indeed possible to install energy-storage systems larger than 20 kWh indoors, if done correctly.

About battery fires – statistics and background

The earlier technical blog post “Post 28 – Fire (4/4) – Energy-storage systems” highlights a key point: the number of fires involving energy-storage systems is still low, but the level of risk is increasing as the market grows [1].

At the same time, home electrical systems are becoming more complex, with solar panels, batteries, EV chargers and control systems. This means:

  • Higher energy density in residential environments.
  • More components that can fail.
  • New failure modes that electrical installers and emergency services must deal with [1,6].

The post also emphasises that most stationary battery energy-storage systems currently use LFP (LiFePO₄), a chemistry with a relatively good fire-safety profile compared with many NMC-based systems [1].

Despite this, the Swedish National Board of Housing, Building and Planning (Boverket) and the industry see a need to:

  • Prevent a single battery fire from quickly affecting the entire home.
  • Facilitate evacuation by limiting the spread of smoke and fire gases.
  • Make it clearer to clients, installers and emergency services how larger batteries should be handled [3–5].

What is a fire compartment?

The purpose of a fire compartment is to confine fire and fire gases to a defined part of the building for a specified period, so that:

Evacuation can take place safely.
The emergency services have time to act.
Damage is limited to one part of the building [2,3].
Boverket states that the requirements for dividing a building into fire compartments are intended to limit the development and spread of fire and fire gases within a building [2].

Some practical key points from Boverket’s guidance on fire compartmentation:

  • The building is divided into fire compartments based on function, use and risk level [2].
  • Areas with particular fire risks should normally form separate fire compartments in order to limit the consequences of a fire for the other parts of the building [2].
  • Fire compartment boundaries (walls, floors, doors and service penetrations) must have a specified fire-resistance rating and retain their function for the stated period [3].

Boverket’s general rules on the spread of fire within a building emphasise that the requirements are intended to limit the consequences of a fire and protect people inside the building [3].

In practice, for you as an installer, this means:

  • You must know whether the area where the battery is installed is a separate fire compartment or part of the same fire compartment as the home [2,3].
  • You need to understand that the requirements are primarily governed by evacuation safety and fire spread, not simply by the fact that the battery itself “is dangerous” [2–4].

New regulations and transitional rules for the siting of energy-storage systems

BFS 2024:7 – Chapter 5, Section 26 (energy-storage systems > 20 kWh)

The Swedish National Board of Housing, Building and Planning’s regulations on safety in the event of fire in buildings (BFS 2024:7) include a new, specific requirement for battery energy-storage systems, among other things [4,5].

The regulations state:

“Energy-storage systems with batteries with a capacity exceeding 20 kWh, commercial kitchens with a particular fire risk, spaces for storing soot and ash, enclosed garages and other spaces with an increased likelihood of fire starting and where a fire can develop rapidly must be designed as a separate fire compartment.

Notwithstanding the first paragraph, such spaces may be located in a fire compartment used for another purpose if a fire can only be expected to have limited consequences for evacuation safety.” [4]

In brief:

  • Main rule: Battery energy-storage systems > 20 kWh in a building must be in a separate fire compartment [4,5].
  • Exception: They may be in the same fire compartment as another use if a fire would have only a limited impact on evacuation safety [4].

Svensk Solenergi summarises that the new building regulations, which come into force on 1 July 2025, specify three requirements for battery energy-storage systems over 20 kWh: fire compartmentation, a fire lobby and the possibility of fire-gas ventilation [5].

Transitional rules

The new rules can be applied already, but installers may choose to use the old rules until mid-2026. That is, the new rules for batteries > 20 kWh formally apply from 1 July 2025 [5,6]. During the transitional period, previous building regulations may be applied in some cases, but the Swedish National Board of Housing, Building and Planning points out that there are substantive reasons for tightening the rules [6].

As an installer, it is important to:

  • Establish which version of the rules applies to the building/project in question (date of planning permission, start notice, alteration work, etc.) [3,4].
  • Clearly explain to the client/customer that even where transitional rules may be applied, the new rules are designed to improve safety [5,6].

What do insurance companies say?

For villas and houses, most insurance companies have no specific requirements for the siting of energy-storage systems. Note that this does not apply to farms, where LBK rules and specific requirements for agricultural installations apply.

For villas, some insurance companies require you to notify them that you have acquired a battery. Others require nothing, and the insurance premium is generally unaffected. The rumour circulating in the solar industry that insurance companies oppose batteries over 20 kWh in a separate fire compartment is therefore not true.

Fire-engineered design – what does it mean for energy-storage systems?

The Swedish National Board of Housing, Building and Planning emphasises that the specified requirements (such as Section 5:26) are one way of meeting the functional requirements—not the only way. It is explicitly “possible to design the building in ways other than those specified in a specific requirement” [2,3].

This allows for fire-engineered design:

  • Instead of strictly following the simplified/“standardised” solution (e.g. a separate fire compartment), the design can be based on calculations, simulations and verified fire-safety analysis [2,3].
  • The aim is to demonstrate that the functional requirements for fire safety and evacuation safety are still met, despite deviations from the specified requirements [3,4].

For energy-storage systems, fire-engineered design could, for example, involve a fire consultant:

  • Analysing the likely fire development in the battery (cell chemistry, casing, built-in fire protection).
  • Assessing fire and smoke development in the space concerned (volume, ventilation, openings).
  • Comparing the time until critical conditions arise in escape routes with evacuation times.
  • Proposing compensatory measures (sprinklers, enhanced fire rating, special ventilation, detection) to ensure evacuation safety is considered adequate [2–4].

Important for you as an installer:

  • Fire-engineered design is normally the responsibility of a fire consultant and the client [3,7].
  • However, you need to recognise when a solution deviates from the “standard requirements” and ensure that there is a documented fire-safety assessment supporting the installation.
  • If the customer wants to do “something other” than use a separate fire compartment for >20 kWh in sensitive locations, you should advise them to involve the client, the appointed control officer and a fire consultant [3,6,7].

Senergia’s interpretation of the regulations and tips for you as an installer

Chapter 5, Section 26 of the regulations explicitly concerns “spaces with an increased likelihood of fire starting” and limiting the consequences for evacuation safety [4].

The key phrase is evacuation safety. In other words, how does the battery’s location affect people’s ability to evacuate safely in the event of a fire? Where is the battery located in relation to escape routes?

Senergia interprets this as follows in the normal case for houses:

  • The question “How large a battery can I install?” is in practice determined by where the battery is located and whether a fire there could jeopardise safe evacuation [3–5].
  • The regulations make no distinction between battery chemistries – the same principles apply to LFP, semi-solid-state, sodium-ion, etc. The requirements are linked to energy capacity, risk level and the building’s fire-safety design, not the cell chemistry [4–6].
  • However, a fire-engineered design that takes into account, for example, the exceptionally higher safety level of semi-solid-state batteries (such as those from Qapasity) is something a fire consultant can incorporate into the overall assessment.
  • The increased safety of semi-solid-state batteries, with their greater resistance to fire and significantly lower likelihood (read: almost impossible) of reaching thermal runaway, are clear arguments in a fire-engineered design.

 

Examples of different locations and guidance on regulations.

Below are examples of typical house scenarios. They are indicative and do not replace design work or decisions by the authorities, but they can help you in discussions with the customer and client.

Example A: Detached garage – no impact on escape safety

  • Scenario: The battery is placed in a separate, detached garage or outbuilding that is not attached to the home.
  • Fire-compartment question: The building is a separate fire compartment from the home [2,3].
  • Escape safety: In normal circumstances, a fire in the garage does not affect the ability to escape from the home.
  • Consequence:
    • In normal circumstances, an unlimited battery size can be installed (from the perspective of section 5:26), provided that other requirements for fire protection, electrical installation and accessibility are met [3–5].
    • Good ventilation, correct installation and the manufacturer's installation instructions remain important.

Example B: Fire-rated boiler room/basement room – no or very limited impact

  • Scenario: The battery is placed in an existing boiler room or other utility room in the basement, designed as a separate fire compartment from the residential area (e.g. with fire-rated walls and a door).
  • Fire-compartment question: The space forms a separate fire compartment [2,3].
  • Escape safety: According to the design, a fire there should not immediately affect escape routes or the residential area.
  • Consequence:
    • An unlimited battery size is normally possible, provided that the fire-compartment construction and any additional requirements (fire-gas ventilation, detection, etc.) are met [4,5].
    • Check that doors have the correct fire rating and that service penetrations are sealed – these are weak points in practice. Practical tip: check the door's fire rating; it indicates the rating of the whole fire compartment.

Example C: Garage in the same fire compartment as the living area – potential impact

  • Scenario: An integrated garage where the wall or door between it and the home does not meet the requirements for forming a separate fire-compartment boundary; in practical terms, it is “the same fire compartment”.
  • Fire-compartment question: The space shares a fire compartment with the home [2,3].
  • Escape safety: A fast-developing battery fire in the garage could directly affect the home and escape routes (smoke spread, heat) [3,6].
  • Consequence (indicative interpretation):
    • There is “potential impact on escape safety” here, which suggests that you should
      • make the garage a separate fire compartment (through renovation), or
      • demonstrate through fire-engineered design that escape safety is still satisfactory [2–4].
    • Without such measures, it is reasonable to expect a practical limit of 20 kWh in this location

Example D: Utility entrance/hall directly connected to escape routes – clear impact

  • Scenario: The battery is placed in a utility entrance, utility room, hall or similar space where people pass daily and where escape routes run.
  • Fire-compartment question: The space is often part of the same fire compartment as the home and close to primary escape routes [2,3].
  • Escape safety: A fire here could quickly block escape routes with heat and smoke.
  • Consequence:
    • It is difficult to argue that the consequences for escape safety are “limited” here.
    • Senergia considers that you should be very cautious about >20 kWh in these locations without extensive fire-safety analysis [3,4].
    • A practical rule of thumb:
      • Utility entrance/passageway to an external door → limit to 20 kWh at most or choose another location.

Example E: Outdoors – no impact (if correctly installed)

  • Scenario: The battery is weather-protected outdoors on a façade, on a stand, on a concrete foundation or in a freestanding enclosure/cabinet.
  • Fire-compartment question: The battery is outside the building; no indoor fire compartment is directly affected [2,3].
  • Escape safety: In normal circumstances, an outdoor fire can be managed without blocking primary indoor escape routes, provided that the location and clearances are well chosen [3–5].
  • Consequence:
    • An unlimited battery size is practically possible from the perspective of section 5:26, provided that:
      distances from the façade, windows and escape doors are reasonable,
    • the manufacturer's requirements for outdoor installation are followed,
    • local guidance or insurance conditions do not impose additional requirements.
      • Svensk Solenergi specifically highlights the recommendation to place batteries outdoors or in separate spaces where possible [5].

No distinction between different battery chemistries in the regulations

The regulations in BFS 2024:7 refer only to “energy-storage systems with batteries with a capacity greater than 20 kWh” – with no distinction between lithium-ion, LFP, semi-solid-state, sodium-ion, etc. [4].

This means:

  • The same 20 kWh threshold formally applies regardless of chemistry [4,5].
  • Although some technologies (e.g. LFP or semi-solid-state) may have a lower probability of thermal runaway and a less severe fire development, this does not change the application of the 20 kWh rule itself [1,5].
  • However, battery chemistry, enclosure and system design may be important parameters in fire-engineered design, where a fire consultant assesses the actual risk level and proposes any exemptions or compensatory measures [2–4].

 

Summary – how large a battery can I install?

For you as an installer, the question “How large a battery can I install in my home?” can be simplified into a few guiding principles:

  • Identify the location first, then the capacity.
    • Detached building, boiler room in a separate fire compartment or outdoors → generally good options for >20 kWh [2–5].
    • Spaces that are part of the dwelling’s fire compartment and close to escape routes → be cautious, plan carefully and involve the right professionals [3,4].
  • 20 kWh → general rule: separate fire compartment under BFS 2024:7 5:26 §, with additional requirements (fire lobby, fire-gas ventilation, etc.) [4,5].
    • Exceptions require an assessment that a fire would have only limited consequences for evacuation safety – often by means of fire-engineered design [2–4].
  • Transitional provisions are no excuse for lower safety standards.
    • Even if older rules may apply for a period, the new requirements were developed to address documented risks associated with larger battery-storage systems [5,6].
  • Battery chemistry does not change the regulations – but it does change the risk profile.
    • LFP, semi-solid-state and sodium-ion may be advantageous from a fire-safety perspective, but the 20 kWh limit still applies [1,4–6].
    • Choose safe products, with well-considered system design and documented safety functions – this also helps with any fire-engineered design [1,5].
  • Division of responsibilities:
    • The installer is responsible for electrically safe installation and compliance with technical instructions.
    • The client is responsible for ensuring that building regulations on fire safety are met, often with support from a certified building inspector and fire consultant [3,7].

By combining:

  • knowledge of the Swedish National Board of Housing, Building and Planning’s requirements [2–4],
  • an understanding of fire-compartmentation and evacuation safety [2,3],
  • and practically sound locations (preferably outdoors or in separate fire compartments) [1,5],

you as an installer can both improve safety and help customers make sound long-term investments in larger energy-storage systems.

 

References

  1. Post 28 – Fire (4/4) – Energy-storage system [Internet]. Stockholm: Senergia; [cited 2025 Dec 23]. Available from: https://senergia.se/teknikblogg/inlagg-28-brand-4-4-energilager/
  2. Fire compartmentation – PBL knowledge bank [Internet]. Karlskrona: Boverket; 2025 [cited 2025 Dec 23]. Available from: https://www.boverket.se/sv/PBL-kunskapsbanken/regler-om-byggande/brandskydd/spridning-inom-byggnad/brandcellsindelning/
  3. Fire spread within buildings – PBL knowledge bank [Internet]. Karlskrona: Boverket; 2025 [cited 2025 Dec 23]. Available from: https://www.boverket.se/sv/PBL-kunskapsbanken/regler-om-byggande/brandskydd/spridning-inom-byggnad/
  4. Boverket’s regulations and general advice (BFS 2024:7) on safety in the event of fire in buildings [Internet]. Karlskrona: Boverket; 2024 [cited 2025 Dec 23]. Available from: https://rinfo.boverket.se/BFS2024-7/pdf/BFS2024-7.pdf
  5. Svensk Solenergi. Building regulations for batteries [Internet]. Stockholm: Svensk Solenergi; [cited 2025 Dec 23]. Available from: https://svensksolenergi.se/byggregler-for-batterier/
  6. Elinstallatören. Can you install more than 20 kWh of battery without a fire compartment at present? [Internet]. Stockholm: Elinstallatören; 2025 Dec [cited 2025 Dec 23]. Available from: https://www.elinstallatoren.se/2025/12/far-man-installera-mer-an-20-kwh-batteri-utan-brandcell-just-nu/
  7. Elinstallatören. Boverket requires a fire compartment for batteries [Internet]. Stockholm: Elinstallatören; 2025 Dec [cited 2025 Dec 23]. Available from: https://www.elinstallatoren.se/2025/12/boverket-kraver-brandcell-for-batterier/

Need help finding the right option?

We know it’s not always easy to know which product or solution is best. Whether you have questions about our range, need guidance or would like help finding a solution that suits your needs, we’re here for you. With our knowledge and experience, we’ll help you make the right choice.

Related posts

Technology blog

This is how a fire safety engineering design is carried out

The new BBR (BFS 2024:7) means that, as a general rule, battery storage systems of over 20 kWh in buildings must be located in their own fire compartment. At the same time, 30–40 kWh systems are now often sold to homeowners, frequently installed indoors...
Salmon swim underwater in a metal structure.
Video

The Salmon Project

Part of Senergia Sustainable Initiatives, a programme that goes beyond traditional material supply. Through the initiative, we create long-term value and actively contribute to a more sustainable future, both within the energy industry and in society at...

The Batteries Regulation and recycling of stationary energy-storage systems

Stationary energy-storage systems are facing a major shift in how they must be designed, documented and recycled. The new EU Batteries Regulation, Regulation (EU) 2023/1542, establishes a comprehensive regulatory framework for the sustainability, safety...

This website uses cookies

Cookies ("cookies") consist of small text files. The text files contain data which is stored on your device. To be able to place some type of cookies we need your consent. We at Senergia AB, corporate identity number 556969-6023 use these types of cookies. To read more about which cookies we use and storage duration, click here to get to our cookiepolicy.

Manage your cookie-settings

Necessary cookies

Check to consent to the use of Necessary cookies
Necessary cookies are cookies that need to be placed for fundamental functions on the website to work. Fundamental functions are for instance cookies that are needed for you to use menus and navigate the website.

Statistical cookies

Check to consent to the use of Statistical cookies
To know how you interact with the website we place cookies to collect statistics. These cookies anonymize personal data.

Ad measurement cookies

Check to consent to the use of Ad measurement cookies
To be able to provide a better service and experience we place cookies to tailor marketing for you. Another purpose for this placement is to market products or services to you, give tailored offers or market and give recommendations on new concepts based on what you have bought from us previously.

Ad measurement user cookies

Check to consent to the use of Ad measurement user cookies
In order to show relevant ads we place cookies to tailor ads for you

Personalized ads cookies

Check to consent to the use of Personalized ads cookies
To show relevant and personal ads we place cookies to provide unique offers that are tailored to your user data